Medical

Introducing diagnosis and treatment at single nerve level

Ingested or injected pharmaceuticals can target specific molecules involved in disease processes, but get distributed throughout the body where they can cause unwanted side effects. An approach known as electroceuticals aims to avoid systemic exposure by using small wires to electrically monitor and manipulate individual nerves that control organ function and carry information about disease.

Despite the promise of electroceuticals, it has been challenging to develop long-term therapies due to the lack of biocompatible wires. Now, NIBIB-funded researches have spun carbon nanotubes into flexible, nerve-sized wires or yarns capable of high-fidelity long-term connections in live animals.

The development of these biocompatible yarns opens the possibility of new bioelectric diagnostics and therapies through regulation of internal organ function at the single nerve level.

All the organs of the body such as the heart, lungs, liver, and kidneys are automatically controlled by nerves that stretch from the brainstem to each organ. These nerves control organ functions such as heartbeat, breathing rates, and blood pressure, making constant adjustments in response to environmental and physiological changes.

Variations in the electrical activity in this area of the brain, known as the autonomic nervous system, can also be predictors, indicators or causes of disease development.

“Monitoring and manipulating the autonomic nervous system to both understand and potentially treat disease has been an intriguing yet understudied approach to medicine,” explains Michael Wolfson, Ph.D., director of the NIBIB program in Rehabilitation Engineering and Implantable Medical Devices.

“This is largely due to technical limitations in being able to insert wires into nerves that can reliably and safely record electrical activity over long periods of time and under different physiological conditions.”

In a study reported in the journal Scientific Reports, bioengineers at Case Western Reserve University in Cleveland, Ohio describe the development of highly flexible carbon nanotube (CNT) yarn electrodes that were capable of months-long electrical recording in major nerves of the autonomic nervous system in rats.

The CNT yarns are essentially, just that, yarns made from a “forest” of hundreds of carbon nanotubes that are pulled from the metal surface they are grown on and spun into a highly flexible, highly conductive wire 1/100th the size of a human hair.

Current technologies for recording electrical signals from nerves include relatively large stiff tungsten needles used by neurologists to obtain readings from single nerves of patients for several hours, but must be removed before causing lasting nerve damage.

Other wire electrode technologies can record nerve signals for short periods but because of their dimensions and stiff mechanical properties they are not suitable for long-term recording in small nerves.

“The currently available electrode technologies simply do not match the mechanical properties of nerves,” explains Dominique Durand, Ph.D., Professor of Biomedical Engineering at Case Western and senior researcher on the CNT yarn work.

“With those types of electrodes, it’s often like sticking glass into spaghetti. Our CNT yarns are similar in size and flexibility to actual nerves. These properties allow them to be stealthily inserted into specific nerves and remain there for months without destroying the tissue or inducing an attack by the immune system.”

The combination of the biocompatibility of the CNT yarns and their outstanding ability to carry an electrical signal that is 10 times stronger than current technologies makes them ideal for long term recording of specific nerve signals.

Finally, the lack of nerve damage keeps the surrounding axons intact, which helps to eliminate background noise. Thus, the CNT yarns have an excellent signal to noise ratio (SNR), which is critical for this type of research.

The group tested the CNT yarns in two major nerves in the autonomic system in rats. One study involved the vagus nerve, which stretches throughout the body to connect to numerous organs. The nerve is known to control and monitor a range of functions including heart rate, digestive tract movement, sweating, and immune response.

CNT yarn electrodes were also inserted into the glossopharyngeal nerve. The nerve is connected to a number of organs including the carotid artery, and parts of the ear, tongue and salivary glands where it is known to be involved in swallowing.

In both nerves, recordings of stable electrical activity were maintained over a 10-week period. Pulses of nerve activity were also monitored while the animal responded to physiological challenges.

The challenges included distension of the rat’s stomach with saline solution, and short durations where the rats were in low oxygen environments.

In each case, the physiological changes induced by the challenge resulted in easily detectable changes in electrical activity that were recorded using the CNT yarn implants over the entire 10-week period of the experiments.


Discover more here.

Image credit: NIBIB.