A 'half-hearted' solution to one-sided heart failure

28th November 2017
Posted By : Enaie Azambuja
A 'half-hearted' solution to one-sided heart failure

Soft robotic actuators, which are pneumatic artificial muscles designed and programmed to perform lifelike motions, have recently emerged as an attractive alternative to more rigid components that have conventionally been used in biomedical devices. In fact, earlier this year, a Boston Children’s Hospital team revealed a proof-of-concept soft robotic sleeve that could support the function of a failing heart.

Despite this promising innovation, the team recognised that many pediatric heart patients have more one-sided congenital heart conditions. These patients are not experiencing failure of the entire heart — instead, congenital conditions have caused disease in either the heart’s right or left ventricle, but not both.

“We set out to develop new technology that would help one diseased ventricle, when the patient is in isolated left or right heart failure, pull blood into the chamber and then effectively pump it into the circulatory system,” says Nikolay Vasilyev, MD, a researcher in cardiac surgery at Boston Children’s.

Now, Vasilyev and his collaborators — researchers from Boston Children’s, the Harvard John A. Paulson School of Engineering and Applied Sciences and the Wyss Institute for Biologically Inspired Engineering at Harvard University — have revealed their soft robotic solution. They describe their system in a paper published online in Science Robotics today.

Although other existing mechanical pumps can help propel blood through the heart, they are designed so that blood must run through the pump itself, exposing blood to its unnatural surface.

“Running blood through a pump always requires a patient to be placed — permanently — on anticoagulant medication to prevent blood clotting,” Vasilyev says, who is senior author on the paper. “It can be very difficult to keep the right balance of medication, especially in pediatric patients, who are therefore at risk of excessive bleeding or dangerous clotting.”

So, using external actuators to help squeeze blood through the heart’s own chamber, the team has designed a system that could theoretically work with minimal use of anticoagulants. “We’ve combined rigid bracing with soft robotic actuators to gently but sturdily help a diseased heart chamber pump blood effectively,” Vasilyev says.

The rigid brace component is deployed via a needle into the heart’s intraventricular septum, the wall of tissue between the heart’s chambers, to prevent the septum from shifting under the pressure of the artificial “muscle” of the soft actuator.

“With the use of classic left ventricular assist devices, there are patients who experience a septum shift towards the right side and subsequent ballooning of the right ventricle, which can cause secondary right heart failure,” Vasilyev says.

“Here, the rigid brace keeps the septum in its original position, protecting the healthy right side of the heart from the mechanical load of the left ventricular assistance.” In contrast, existing ventricular assist devices (VAD) don’t involve the septum at all.

Altogether, the system involves a septal anchor, a bracing bar and sealing sleeve that pass through the ventricle wall, and a frame embedded with soft actuators that is mounted around the ventricle. The researchers designed two distinct versions of the system for the right and left ventricle.

In animal studies, the soft robotic system contributed significantly to the diseased ventricle’s ability to eject blood. The researchers speculate that the system’s effectiveness is due in part to its integration with the septum, which plays a key role in the heart’s ability to pump blood.

The system also made significant improvement in its ability to draw blood into the ventricles, which is just as important as the heart’s ability to pump it out. “As the actuators relax, specially-designed elastic bands help return the heart’s wall to its original position, filling the chamber sufficiently with blood,” Vasilyev says.heart

Based on these initial proof-of-concept results, Vasilyev and his team are working on key design modifications that can bring this system closer to use in humans, such as portability and miniaturisation of the components. They also need to do longer tests in animals to see how the system impacts the heart over prolonged periods of time.


You must be logged in to comment

Write a comment

No comments




Sign up to view our publications

Sign up

Sign up to view our downloads

Sign up

SPS IPC Drives 2019
26th November 2019
Germany Nuremberg Messe
Vietnam International Defense & Security Exhibition 2020
4th March 2020
Vietnam National Convention Center, Hanoi